Glow Energy UPS incorporates the world’s latest PWM based technology which provides you complete comfort during the failure of utility power & provide your appliance the exact replication of main power.
Parameters |
Normal Mode |
UPS Mode |
Mains AC Lower Voltage Limit |
100 +5 VAC |
180 + 5 VAC |
Mains AC Lower Recovery Volt. |
110 +5VAC |
190 + 5 VAC |
Mains AC Higher Voltage Limit |
280 +5 VAC |
260 + 5 VAC |
Mains AC Higher Recovery Volt |
270 + 5 VAC |
250 + 5 VAC |
Output Voltage with full load in ECO/ Normal Mode |
220 + 10 V |
Battery Low Cut-Off Voltage |
10.4 + 0.2 V (per Batt.) Default |
Mains 0/p Frequency |
Same as Input |
INV. 0/p Frequency |
50 + 1.0 Hz |
Battery Charging
Battery Charging Volt. Range |
100 to 280 V |
180 to 260 V |
Trickle Charging Current Limit |
0.5 + 0.3A |
0.5 ± 0.3A |
Boost Voltage |
14.4 + 0.1 V (per Batt.) |
14.4 + 0.1 V (per Bat) |
Float Voltage |
13.6 + 0.2 V (per Batt.) |
13.6 + 0.2 V (per Bat) |
Overload |
100 + 3% (with Auto reset function |
100 + 3% (with Auto reset function |
Short Circuit Protection |
> 300% Load (with manual reset function) |
> 300% Load (with manual reset function) |
Change Over Time |
< 60 mSec |
< 10 mSec |
Max. Charging Current (when battery Is fully discharged) (H.C.)
2.75KVA |
3.75KVA |
5.5KVA(48V) |
5.5KVA(96V) |
7.5-20KVA |
16±1 |
18±1 |
24±1 |
16±1 |
16±1 |
Inverter Rating Available :
- 3.6 KVA, 5 KVA, 7 KVA, 10 KVA
Reviews